McqMate
These multiple-choice questions (MCQs) are designed to enhance your knowledge and understanding in the following areas: Mechanical Engineering .
Chapters
1. |
Co-efficient of performance of vapour absorption refrigeration system as compared to that for vapour compression refrigeration system is |
A. | more |
B. | less |
C. | may be more or less |
D. | un - predictable |
Answer» B. less |
2. |
The function of compressor in vapour compression refrigeration system is performed in vapour absorption system by |
A. | generator |
B. | absorber |
C. | generator, absorber and liquid pump |
D. | absorber and liquid pump |
Answer» C. generator, absorber and liquid pump |
3. |
In vapour absorption refrigeration system heating in generator is done at 100°C, refrigeration in evaporator at 10°C and cooling by cooling water in condenser at 30°C. The (COP)max is |
A. | 0.5 |
B. | 0.35 |
C. | 2 |
D. | in sufficient data |
Answer» B. 0.35 |
4. |
Electrolux system of refrigeration has |
A. | only one liquid pump |
B. | only two liquid pumps |
C. | no liquid pump |
D. | none of the above |
Answer» C. no liquid pump |
5. |
Electrolux refrigerators has the following working substances |
A. | Hydrogen |
B. | Ammonia and Hydrogen |
C. | Ammonia and water |
D. | Ammonia, hydrogen and water |
Answer» D. Ammonia, hydrogen and water |
6. |
Which of the following system can be called as mechanical system of refrigeration |
A. | Vapour absorption system |
B. | Vapour compression system |
C. | Steam jet refrigeration system |
D. | None of the above |
Answer» B. Vapour compression system |
7. |
The vapour absorption refrigeration system using Ammonia – water has cycle operating pressures |
A. | higher than that using Lithium Bromide – water |
B. | lower than that using Lithium Bromide – water |
C. | may be higher or lower depending upon application |
D. | higher for sub-zero application and lower for above zero application |
Answer» A. higher than that using Lithium Bromide – water |
8. |
Shaft work required for vapour absorption system to produce 1 ton refrigeration may be only |
A. | 50 to 60% of that required for vapour compression system |
B. | 20 to 30% of that required for vapour compression system |
C. | 1 to 2% of that required for vapour compression system |
D. | none of the above |
Answer» C. 1 to 2% of that required for vapour compression system |
9. |
Work of compression of the fluid in vapour absorption refrigeration system as compared to that for vapour compression refrigeration system is |
A. | les |
B. | more |
C. | may be more or less |
D. | un - predictable |
Answer» A. les |
10. |
Munters Platen system of refrigeration is |
A. | Vapour absorption system with ammonia and water |
B. | Vapour compression system with ammonia as working substance |
C. | Electrolux system with Hydrogen, ammonia and water as working substances |
D. | none of the above |
Answer» C. Electrolux system with Hydrogen, ammonia and water as working substances |
11. |
Electrolux refrigerators is |
A. | Vapour compression refrigerator with one compressor |
B. | vapour absorption refrigerator with no pump |
C. | vapour absorption refrigerator with one aqua pump |
D. | None of the above |
Answer» B. vapour absorption refrigerator with no pump |
Done Studing? Take A Test.
Great job completing your study session! Now it's time to put your knowledge to the test. Challenge yourself, see how much you've learned, and identify areas for improvement. Don’t worry, this is all part of the journey to mastery. Ready for the next step? Take a quiz to solidify what you've just studied.